RM新时代有限公司

雙組份打膠機(jī)廠(chǎng)家詳解關(guān)于電機(jī)線(xiàn)圈失效原因!

時(shí)間:2021-07-21 來(lái)源:http://m.ruiyingjituan.com/ 發(fā)布人:昌盛機(jī)械

當(dāng)電機(jī)處于非正常工況(包括電氣、機(jī)械和環(huán)境方面)時(shí),電機(jī)線(xiàn)圈的壽命會(huì)嚴(yán)重降低。風(fēng)機(jī)盤(pán)管故障的原因有:缺相、短路、盤(pán)管接地、過(guò)載、轉(zhuǎn)子閉鎖、電壓不平衡、浪涌。下面是各種線(xiàn)圈故障,雙組份打膠機(jī)可以幫助您正確識(shí)別故障原因(以四極電機(jī)為例)。
When the motor is in abnormal conditions (including electrical, mechanical and environmental aspects), the life of the motor coil will be seriously reduced. The causes of fan coil unit failure are: lack of phase, short circuit, coil grounding, overload, rotor locking, voltage imbalance, surge. The following is a variety of coil faults, two-component glue machine can help you correctly identify the cause of the fault (take quadrupole motor as an example).
1.新線(xiàn)圈
1. New coil
2.缺相
2. Phase loss
缺相是指電源中某一相的開(kāi)路。主要原因是一相熔斷器燒斷、接觸器打開(kāi)或一相電源線(xiàn)斷掉。
Open phase refers to the open circuit of a phase in the power supply. The main reason is that one phase fuse is burnt out, contactor is opened or one phase power line is broken.


在四極電機(jī)缺相燒壞的圖片中,電機(jī)線(xiàn)圈對(duì)稱(chēng)燒壞的意思是缺相燒壞。當(dāng)缺相導(dǎo)致星形連接燒壞時(shí),2極電機(jī)只有2組線(xiàn)圈是好的,4極電機(jī)只有4組線(xiàn)圈是好的;如果三角連接缺相燒壞,兩極電機(jī)的2組線(xiàn)圈和四極電機(jī)的4組線(xiàn)圈是好的。
In the picture of four pole motor with missing phase and burning out, the symmetrical burning out of motor coil means missing phase and burning out. When the star connection is burnt out due to phase loss, only two groups of coils of 2-pole motor are good, and only four groups of coils of 4-pole motor are good; If the delta connection is burned out, the two coils of two pole motor and the four coils of four pole motor are good.
3.短路
3. Short circuit
電機(jī)故障是由污染、磨損、振動(dòng)等原因引起的。
Motor failure is caused by pollution, wear, vibration and other reasons.
4.線(xiàn)圈接地
4. Coil grounding
電機(jī)故障是由污染、磨損、振動(dòng)等原因引起的。
Motor failure is caused by pollution, wear, vibration and other reasons.
5.過(guò)載
5. Overload
電機(jī)過(guò)載會(huì)導(dǎo)致電機(jī)過(guò)載。
Motor overload will cause motor overload.
6.轉(zhuǎn)子鎖定
6. Rotor locking
這種情況會(huì)使電機(jī)發(fā)熱很多,有可能是由于電機(jī)頻繁啟動(dòng)或頻繁反轉(zhuǎn)。
This situation will make the motor heat a lot, may be due to frequent motor start or frequent reversal.
7.三相不均勻電壓
7. Three phase uneven voltage
電壓不均勻會(huì)導(dǎo)致絕緣損壞。原因可能是電源不穩(wěn)定,電線(xiàn)沒(méi)有連接好。
Uneven voltage can cause insulation damage. The reason may be that the power supply is unstable and the wires are not well connected.
注意:1%的電壓不平衡將導(dǎo)致6%到10%的電流不平衡。
Note: a 1% voltage imbalance will result in a 6% to 10% current imbalance.
8.飆升
8. Soaring
一般是由浪涌引起的。電涌可能由電網(wǎng)、雷電、電容器和其他電氣設(shè)備引起。
It is usually caused by surge. Surge may be caused by power grid, lightning, capacitors and other electrical equipment.